1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
HINT: At the time of installation, first evacuate air from refrigeration system.
Then, charge the system with the refrigerant and inspect for leaks of the refrigerant.
Specified amount: 1,050 +- 50 g (37.03 +- 1.76 oz.)
2. DISCONNECT LIQUID AND SUCTION TUBES
(a) Using SST, remove the 2 piping clamps.
SST 09870-00025 (Liquid tube) 09870-00015 (Suction tube)
HINT: Confirm the direction of the piping clamp claw and SST referring to the illustration on the caution label.
NOTICE: Be careful not to deform the tubes when pushing SST.
(b) Disconnect the both tubes.
NOTICE: Cap the open fittings immediately to keep moisture or dirt out of the system.
HINT: At the time of installation:
3. REMOVE INSTRUMENT PANEL AND REINFORCEMENT (BO-84 )
4. REMOVE ANTENNA RELAY
(a) Disconnect the connector.
(b) Remove the 2 screws and antenna relay.
5. REMOVE COOLING UNIT
(a) Disconnect the connector.
(b) Remove the 4 screws, 2 nuts and cooling unit.